ARECA EMBEDDED SYSTEMS PVT LTD
 
Home  |  About Us  |  Quality Policy  |  Products  |  Brochure  |  Careers  |  Contact Us
Products
 Telecom BTS Site Sector
» Intelligent Power Management Unit
» Auto BTS Site Manager
» Auto BTS Site Alarm Manager
» Aviation Warning Lamp
» DC Energy Meter 4 channel version
» Alarm PFC Expander
» Fire Alarm
 Railway Sector
» Led based Train information displays
» GPS based clock
» GPS based In-Train Location display system
» Led Signal Aspects(Main Signal) for railway applications
 Defence Sector
» Handled Cable Tester
» Fiber optic voice,data, telemetry links
» Universal Multiplex
» PCI bus based GPS time Synchronizer
» Synchronized IRIG Time Code Reader / Generator
 Others
» Contactless Smart Card Based Passenger Control System
» Vehicle Fleet Tracking Software ViewWay: GPS, GPRS, WebServer based
   Fire Alarm  
 
  Download
 

The Fire Alarm Panel supports 4 zones, each of which can be used for fire/smoke detection or intruder detection (security). The selection of fire or intruder detection is done internally, by using a DIP switch. Each zone can support up to 8 sensors. Two potential free change-over contacts, one each for fire and security, are provided to extend the alarm to remote sites.

When used for fire detection, any fire sensor in the zone getting activated will trigger the alarm condition. Corresponding LED on the Panel will glow and internal buzzer will start making sounds enabling the external Hooter to sound and the potential free contact changes state. The fire shall be acknowledged by using the key switch on the front of the Fire Alarm Panel. On acknowledging, the hooter will go off but the buzzer will remain ON, reminding of the fault. Once the fault has been attended to (fire put off) the alarm shall be reset clearing the alarm.

 

Trying to reset the alarm without attending to the fault will cause the hooter to go ON again. When used for intruder detection, door opening will trigger the Alarm. The person opening the door is given 30 seconds time to acknowledge the door opening using the key switch on the panel. During this time and 30 seconds after the acknowledgement, the buzzer remains ON as a reminder. If the door opening is not acknowledged in 30 seconds, the hooter will switch ON and the potential free contact changes state. The door shall close only when acknowledged, else the alarm will trigger again.

 
Specifications
Input Voltage : -48V DC (230V 50Hz option also available)
Operating Voltage : 12 V DC (Battery backup available as option for mains operated model only)
LED Indications : POWER ON
ON BATTERY
FIRE FAULT
SECURITY FAULT
ZONE OPEN
Controls : 2 Position Key Switches
One key switch for FAULT acknowledgement
One push button switch for zone reset
Ambient Temperature : 0 - 50°C
No. of Zones : Four (Selectable as Smoke/Fire, Security)
Sensors /zone : Upto eight
Intrusion timeout : 30 sec
Current Ratings for Zones
  Fire Zone
        Normal
        Alarm
  Security Zone
        Normal
        Alarm
:

5mA
100mA (max)

5mA
100mA (max)
Hooter : Current 0.5A max.
(Number of hooters limited to maximum current drawn of 0.5A.)
Battery : 12V, 4.2Ah, (12V, 7Ah Option also available)
Remote indication : Independent potential free contacts for fire and security zone.
Physical Dimensions : 235(L) X165(H) X93(D) mm3